Advertisements
[AdSlot: TOP-1 • Reserved Container • CLS-Safe]

Emergency Heat on Heat Pump Cost: When to Use It and Rates

Direct Answer: A furnace that is not working usually stems from five common issues: a tripped circuit breaker, an emergency shutoff switch flipped off, a clogged furnace filter triggering high-limit switches, incorrect thermostat settings, or an electronic igniter failure. Check external switches, mode settings, and filter airflow before scheduling an emergency service call.

Advertisements
[AdSlot: ART-1 • Reserved Container • CLS-Safe]
Table of Contents

Understanding your emergency heat on heat pump cost is crucial during severe winter weather because running emergency heat can easily double or triple your daily heating expenses compared to standard compressor operation.

According to the U.S. Department of Energy, modern air-source heat pumps can reduce electricity use by 50% compared to furnaces and electric resistance baseboard heaters, saving homeowners an average of over $500 per year.

When you switch your thermostat to emergency heat, you bypass this high-efficiency thermodynamic compressor cycle completely, relying exclusively on energy-intensive electric resistance heat strips.

Understanding how emergency heat works prevents staggering electric utility bills while ensuring your family stays warm when the outdoor heat pump encounters mechanical trouble.

What Is Emergency Heat on a Heat Pump?

Emergency heat (“EM HEAT”) is a manual thermostat setting designed to keep your home warm when the outdoor heat pump unit breaks down, loses power, or is completely disabled by mechanical damage.

In standard heating mode, your outdoor heat pump absorbs ambient thermal energy from outdoor air using chemical refrigerant and transfers it indoors. When emergency heat is manually selected, the thermostat locks out the outdoor compressor and fan entirely. Instead, indoor comfort relies 100% on supplemental electric resistance heat strips mounted inside your indoor air handler cabinet.

These electric resistance coils function exactly like a giant toaster, drawing massive electrical amperage to heat air passing through the ductwork.

Next in this series: If your outdoor heat pump fails to produce warmth during freezing weather, troubleshoot mechanical issues in our guide to heat pump not heating.

What Is the Difference Between Aux Heat and Emergency Heat?

Many homeowners use the terms “Auxiliary Heat” and “Emergency Heat” interchangeably, but they represent two distinct operating modes:

  • Auxiliary Heat (“AUX HEAT”) - Auxiliary heat operates automatically as a supplement to the heat pump compressor. When outdoor temperatures drop below the thermal balance point (typically between 25°F and 35°F) or when you raise the thermostat setpoint more than 2 to 3 degrees, the thermostat temporarily energizes electric heat strips to assist the compressor. Both systems run simultaneously.

  • Emergency Heat (“EM HEAT”) - Emergency heat is engaged only through manual homeowner selection at the thermostat. It completely turns off the outdoor compressor and runs only the electric resistance heating elements.

The following comparison table highlights the mechanical and operational differences between these two heating stages:

System Parameter Standard Heat Pump Mode Auxiliary Heat (AUX) Emergency Heat (EM HEAT)
Outdoor Compressor Running continuously Running continuously Completely locked out (OFF)
Indoor Heat Strips Off Energized as temporary supplement Energized as 100% heat source
System Activation Automatic by thermostat Automatic when extra heat needed Manual homeowner selection
Energy Efficiency High (COP 2.0 to 3.5) Moderate combined efficiency Very low (COP 1.0)
Operational Cost Lowest winter heating cost Moderate temporary cost Highest possible utility cost

How Much More Does Emergency Heat Cost to Run?

The primary reason emergency heat is so expensive is thermodynamic efficiency. A heat pump operating in mild weather delivers 2 to 3.5 units of heat energy for every 1 unit of electrical energy consumed. Electric resistance coils deliver exactly 1 unit of heat for every 1 unit of electricity (COP 1.0).

Typical residential electric resistance heat strips are sized between 5 kW and 20 kW depending on home square footage:

  1. Calculate Hourly Wattage Consumption: A standard 10 kW auxiliary electric heat package consumes 10 kilowatt-hours (kWh) of electricity for every continuous hour of operation.

  2. Evaluate Daily Operational Expense: In freezing weather, heat strips can easily run 12 to 16 hours per day to maintain indoor temperatures. Running a 10 kW heat strip for 15 hours consumes 150 kWh of electricity daily.

  3. Assess Monthly Utility Impact: Depending on regional electricity rates, running emergency heat as your primary heating source for several weeks can add $300 to $600+ to a single monthly electric bill.

If mechanical failures force you to use emergency heat while awaiting repairs, professional diagnostic service visits cost $100 to $250 according to Angi.

When Should You Turn Emergency Heat On?

Because emergency heat is so expensive to operate, you should activate it only under specific, necessary conditions:

  1. Outdoor Unit Is Mechanically Damaged: If severe winter storms cause falling tree limbs to crush the outdoor fan grille or damage refrigerant piping, switch to emergency heat immediately to maintain household warmth while awaiting emergency repairs.

  2. Outdoor Coil Is Encased in Thick Solid Ice: If a defrost control board failure causes solid ice to build up and completely encase the outdoor compressor cabinet, switch to emergency heat to prevent compressor motor burnout until a technician can de-ice the unit.

  3. Compressor Failure or Electrical Short: If the outdoor unit trips electrical breakers repeatedly, emits loud grinding screeching noises, or stops operating entirely, emergency heat prevents household plumbing pipes from freezing during severe winter cold snaps.

For a broader overview of air-source heating technology, read our guide to the air source heat pump.

Why Does Emergency Heat Come on by Itself?

Thermostats are designed so that emergency heat never activates automatically on its own. If you see an indicator light or display message, it is critical to distinguish between “AUX” and “EM HEAT”:

  • Normal Defrost Cycle Operation - During winter defrost cycles, your heat pump temporarily shifts into cooling mode to melt outdoor coil frost. During this 5 to 10 minute cycle, auxiliary heat strips automatically turn on to temper indoor supply air. The thermostat may display an “AUX HEAT” message during this period, which is completely normal.

  • Large Thermostat Temperature Jumps - If you adjust your thermostat setpoint upward by more than 2 or 3 degrees at once, the system algorithm assumes rapid recovery is required and automatically engages auxiliary heat strips until room temperature nears the target.

  • Accidental Manual Selection - If your thermostat displays “EM HEAT”, a family member likely engaged emergency heat manually at the control panel. Switching the system mode back to “HEAT” restores standard compressor operation.

To evaluate overall operating expenses between different equipment options, explore our comprehensive analysis of furnace vs heat pump cost.

Frequently Asked Questions

Will running emergency heat damage my heat pump?

No. Running emergency heat will not physically harm your heat pump because the outdoor unit is safely shut down. However, it will cause your monthly electric utility bills to skyrocket due to the continuous high wattage consumption of electric resistance coils.

Should I switch to emergency heat during a winter snowstorm?

No. Do not switch to emergency heat simply because it is snowing or cold outside. Modern heat pumps are engineered to run down to freezing temperatures. Keep snow cleared from around the outdoor unit, and let the system run in standard “HEAT” mode.

What temperature should emergency heat be set to?

If you are forced to run emergency heat due to a mechanical breakdown, lower your thermostat setpoint to 65°F to 68°F. Lowering the setpoint reduces the continuous operating hours of the electric heat strips, helping minimize utility bill spikes while protecting indoor plumbing pipes.

Why is my emergency heat blowing cool air?

Electric heat strips should deliver warm air between 100°F and 115°F. If the air feels cool, an internal high-temperature limit switch may have tripped, a sequencer relay may have failed, or the dedicated double-pole circuit breaker powering the heat strip package may have tripped.

Ready to Optimize Your Heat Pump’s Winter Efficiency?

Understanding emergency heat operation protects your household budget from unexpected electric bill spikes while ensuring dependable emergency warmth during equipment breakdowns.

Troubleshoot cold air symptoms, reversing valve faults, and outdoor coil freeze-ups in our diagnostic guide for when your heat pump not heating.

Advertisements
[AdSlot: ART-2 • Reserved Container • CLS-Safe]
Safety Warning: High voltage electrical wiring, gas lines, and pressurized refrigerant lines present severe shock, fire, explosion, or toxic gas hazards. Always shut off power at the main breaker before inspecting components. Refrigerant handling requires federal EPA certification. Gas valve and heat exchanger repairs must be performed by a licensed professional technician.
Advertisements
[AdSlot: END-1 • Reserved Container • CLS-Safe]

ComfortBench Editorial Team

HVAC Research & Editorial Staff

The ComfortBench Editorial Team researches, develops, and fact-checks practical HVAC replacement cost benchmarks and safe homeowner troubleshooting guides.

Technically reviewed by a licensed HVAC professional on 2026-11-21

Advertisements
[AdSlot: MPX-1 • Reserved Container • CLS-Safe]